A workstation will lose trust with the domain controller if its account has been overwritten. It is entirely In 7 or above the client won't try until it has a connection to a DC. and examining the logs for why the schannel failed to setup. The 'why' is that in Microsoft Windows they extended their directory . Windows Server How-To This error message stated that the trust relationship between the workstation and the primary domain failed. In other words, getting rid of a computer account can cause some pretty serious. How do you resolve this issue on Windows 7: "The security server does not have a computer account for this workstation trust relationship"?.

In doing so, they accomplished basically the same thing that they would have if they had performed an authoritative restoration on a domain controller in a larger organization. Although the restore operation succeeded, it had some unforeseen consequences. After the restoration, all of the other servers in the domain displayed an error message at log in. This error message stated that the trust relationship between the workstation and the primary domain failed.

You can see the actual error message in Figure 1. The reason why this problem happens is because of a "password mismatch. However, in Active Directory environments each computer account also has an internal password.

trust relationship failed windows 7 cause

If the copy of the computer account password that is stored within the member server gets out of sync with the password copy that is stored on the domain controller then the trust relationship will be broken as a result. So how can you fix this error? Unfortunately, the simplest fix isn't always the best option. The easy fix is to blow away the computer account within the Active Directory Users and Computers console and then rejoin the computer to the domain.

Doing so reestablishes the broken-trust relationship. This approach works really well for workstations, but it can do more harm than good if you try it on a member server.

The reason for this has to do with the way that some applications use the Active Directory. Take Exchange Server, for example.

Exchange Server stores messages in a mailbox database residing on a mailbox server. However, this is the only significant data that is stored locally on Exchange Server. All of the Exchange Server configuration data is stored within the Active Directory.

In fact, it is possible to completely rebuild a failed Exchange Server from scratch aside from the mailbox database simply by making use of the configuration data that is stored in the Active Directory. The reason why I mention this particular example is that the Exchange Server configuration data is stored within the computer object for that server.

When you connect the computer to Active Directory domain it sets a password like for AD users.

Fix Trust relationship failed issue without domain rejoining – TheITBros

Trust at this level is provided by the fact that operation is performed by Domain administrator or another user with the same rights. Each time when domain computer login to the domain, it establish a secure channel with a domain controller and send credentials. In that case, trust is established between the workstation and domain and further interaction occurs according to administrator-defined security policies.

The computer account password is valid for 30 days by default and then automatically changes. It is important to understand that the change of password initiated by computer is defined by Domain policies.

Error: The trust relationship between this workstation and the primary domain failed

This is similar to the changing user password process. You can configure maximum account password age for domain computers using GPO Domain member: Maximum machine account password age, which is located in the following GPO editor branch: You can specify number of days between 0 and by default it is 30 days.

For a single machine, you can configure the machine account password policy through the registry. To do this, run regedit.

trust relationship failed windows 7 cause

Edit the value of the MaximumPasswordAge parameter, in which you can specify the maximum period of validity of the computer password in the domain in days. Other option is to completely disable sending a request for computer password updates, by changing the value of the DisablePasswordChange parameter to 1.

DON’T REJOIN TO FIX: The trust relationship between this workstation and the primary domain failed

The Active Directory domain stores the current computer password, as well as the previous one just in case. If the password was changed twice, the computer that is using old password will not be able to authenticate in the domain and establish a secure connection.

If the password has expired, computer changes it automatically when login on the domain. Therefore, even if you did not Power on your computer for a few months, trust relationship between computer and domain still be remaining and the password will be changed at first registration in the domain.

DON’T REJOIN TO FIX: The trust relationship between this workstation and the primary domain failed

Trust relationship failed if computer tries to authenticate on domain with an invalid password. Typically, this occurs after reinstalling the OS, then the system state was restore from an image backup or snapshot of the Virtual machine, or it was just turned off for a long time. In this case, the current value of the password on the local computer and the password in the domain will be different.

trust relationship failed windows 7 cause

The most obvious classic way to restore trust relationship is: Reset local Admin password Move computer from Domain to workgroup Reboot Reset Computer account in the domain using ADUC console Rejoin computer to the domain Reboot again This method is the easiest, but not the fastest and most convenient way and requires multiple reboots.

Also, we know cases when user profile is not reconnecting correctly after rejoining.